Skip to Content

Diesel generator set - CUMMINS BC-DC264D-50(211 kW / 264 kVA)

https://www.bochipower.cc/web/image/product.template/15961/image_1920?unique=9b4d277
(0 review)

BOCHI POWER gensets from Cummins use genuine Cummins engines with a PT injection pump, alloy steel crankshaft and connecting rods. The engine, alternator and control unit are manufactured, tested and inspected by BOCHI POWER, which guarantees reliable starting, low fuel consumption and a long service life.

ModelBC-DC264D-50
Standby power264 kVA / 211 kW
Prime power250 kVA / 200 kW
Engine6LTAA8.9-G2
Frequency50 Hz
VoltageMultivoltaje 110/208 - 277/480 V
PhasesTrifásico, cuatro hilos
Dimensions (mm)2600 x 1000 x 1600
TypeAbierto

Manufactured, integrated and tested by BOCHI POWER.

$ 18,925.99 18925.99 USD Tax Excluded

18,925.99 Bs Tax Excluded

  • Brand
  • Model
  • Engine Model
  • Voltage (V)
  • Power (kW)
  • Emission Standards
  • Phases
  • Generator set model
  • Generator set series
  • Generator set structure type
  • Rating (kVA)

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Overview

Rated Diesel Generator Set - CUMMINS BC-DC264D-50 (211 kW / 264 kVA) standby, the BC-DC264D-50 comes built around a 6LTAA8.9-G2 engine, in open type configuration, and delivers 50 Hz, three-phase four-wire, at 110/208 V – 277/480 V.

At this rating the set backs up a whole building or production line: process plants, industrial units and commercial centres where an outage is not an inconvenience but a production stop with a direct cost. BCP’s Cummins range spans 28 to 2090 kVA with Cummins power, intended for standby duty and for extended running depending on how the fuel and cooling system is specified.

Typical applications

  • Industrial units and process plants
  • Logistics and distribution centres
  • Hospitals and corporate buildings
  • Food and beverage plants
  • Infrastructure and civil works

Standby and prime ratings

The standby rating (264 kVA / 211 kW) is what the set delivers during a grid outage, for a limited number of hours a year and without sustained overload. The prime rating (PRP) allows continuous duty with varying load. Sizing starts from the real load in kW, corrected by power factor, with headroom left for motor starting.

Frequently asked questions

What is the difference between standby and prime?

Standby is the power available in an emergency, limited to a set number of hours a year; prime is what the set can sustain continuously with varying load. A set sized for standby should not be used as prime generation without re-checking the duty.

What voltage and connection does the BC-DC264D-50 deliver?

It is offered at 110/208 V – 277/480 V, three-phase four-wire, 50 Hz. Final nameplate voltage is fixed at order stage according to the site network and the transfer arrangement.

Is one set of this size better than two smaller ones?

It depends on criticality. A single set simplifies maintenance and footprint; two units give N+1 redundancy but double the capital cost and the service plan.

More from the range

Full Cummins range: Cummins diesel generator sets · all series and ratings · generator set catalogue · request a quote.

Similar power ratings

Specifications

Characteristics
Brand CUMMINS
Model BC-DC264D-50
Engine Model 6LTAA8.9-G2
Voltage (V) 110/208V 127/220V 230/400V 254/440V 277/480V
Power (kW) 211
Emission Standards T 2
Phases Three-phasefour-wire
Generator Set
Generator set model BC-DC264D-50
Generator set series Diesel engine series
Generator set structure type Open skid
Others
Rating (kVA) 264